- New
Flush-mounted three-electrode LPR probe (working, counter, reference) for instantaneous corrosion rates; pigging compatible. Fixed or adjustable.
ATEX / IECEx documentation supplied where stated
Incoterms agreed in each quotation
Price, lead time and certificates in every offer
The Flush LPR probe with three electrodes (working, counter and reference) is mounted flush with the pipe wall, allowing pigging without interference; it is used where the probe cannot extend into the line. Mild steel electrodes, epoxy seal. Fixed and adjustable versions are available.
Linear Polarisation Resistance (LPR) is an electrochemical method giving an instantaneous corrosion rate in conductive environments: a small potential of 10 to 20 mV is applied between identical electrodes and the resulting current gives the polarisation resistance, which is inversely related to the corrosion rate. LPR probes are recommended for water systems, oil systems with high and continuous water cut and condensation corrosion, and are ideal to follow corrosion inhibitor performance with almost instant feedback.
The probe is mounted through a EuropCorr Hollow Plug Assembly and is used with both 2" high-pressure mechanical and hydraulic access systems; with the Retrieval Tool and Service Valve it can be changed or inspected without shutdown. Readings are taken with the MaxiCorr portable instrument through the 6-pin connector (S-type connector on request) or continuously with the MegaCorr data logger.
Specifications
| General | |
|---|---|
| Manufacturer | EuropCorr (Italy) |
| Compatible system | EuropCorr 2" mechanical and hydraulic access systems (hollow plug) |
| Connector | 6-pin (S-type on request) |
| Body material | AISI 316L (special materials on request) |
| Standards | ISO 9001, NACE MR0175 / ISO 15156 |
| Ordering information | |
|---|---|
| Version | Part No. |
| Fixed | 352002 |
| Adjustable | 352007EX |
| Adjustable probe length (EX) | |
|---|---|
| Code | Length (mm) |
| E1 | 55 to 70 |
| E2 | 70 to 95 |
| E3 | 95 to 135 |
| E4 | 135 to 180 |
| E5 | 180 to 230 |
| E6 | 230 to 280 |
| E7 | 280 to 330 |